Accessories - NOA 280i
The following accessories are available for the NOA 280i:
|
|
|
| |
|
|
| Exhaled Breath |
| Part Number |
Item |
| CRBK 01400 |
On-Line NO Breath Kit |
|
| |
For measurement of on-line exhaled NO. The kit includes restrictors calibrated to give flows of 30, 50, 100, 150 200 and 250 mL/s BTPS at ~ 10-15 cm H2O mouth pressures. |
| CBSK 01410 |
ATS Compliant Bag Collection and Sampling Kit |
|
| |
This kit includes an inspiratory gas filter to reduce the concentration of NO in inspired air to < 5 ppb and 12 L Mylar® bags to collect the entire vital capacity at a flow rate of 350 mL/s. The bags are equipped with Luer caps to seal the bag after sample collection. The kit includes adapters and three-way valves for analyzing the samples using the NOA.
|
| CBSK 01400 |
Dead-space Discard Bag Collection and Sampling Kit |
|
| |
The kit includes the inspiratory gas filter and a valve in the body of the filler to permit discard of the first few hundred milliliters of exhaled breath, then collect the remainder of the breath.
|
| CNDK 01400 |
ENO Calibration Gas |
|
| |
Calibration of the NOA for gas-phase measurements is easily performed using this lightweight, disposable cylinder of 45 ppm NO in N2.
|
CACT 01400 |
Zero Air Filter |
|
| |
Calibration of the NOA for gas measurement also requires a gas contains low levels (< 1 ppb) of NO. This is easily produced from room air using a cartridge containing KMnO4 and activated carbon. The trap has sufficient capacity for several years of use.
|
CNCK 01400 |
Calibration Kit |
|
| |
Includes the Zero Air Filter, ENO Calibration gas cylinder, a low flow regulator preset to 300 mL/min gas and a calibration tee.
|
CAFL 01420 |
Bacterial/Viral Filters |
|
| |
These single-subject disposable bacterial and viral filters provide > 99.9% filtration efficiency for use with the On-Line NO breath kit and the Bag Collection and Sampling Kits. Package of 50.
|
CACC 01420 |
Thermal Mass Flowmeter |
|
| |
On-line measurement of exhaled NO requires exhalation at a constant flow rate. The TSI thermal mass flowmeter permits direct measurement of the exhalation flowrate using the NOA 280i or the NOA 280 equipped with the flowmeter upgrade kit (Part # ACC 01487-01).
The flowmeter is installed on the On-Line NO Breath kit and the signal processed by the NOA. Calibration is performed using standard calibration syringes (1-3 L) and the NOAnalysis 3.21 REB program.
The flowmeter has a fast response time (4 msec) and low pressure drop. The 25.4 mm OD ISO-taper outlet fits over the Accurate NO breath kit mouthpiece and a 22 mm OD ISO-tapered inlet fits the NOA bacterial and viral filters. The polycarbonate body is compatible with standard cold sterilization agents.
The flowmeter employs two sensors; a platinum film sensor is heated and maintained at a constant temperature to measure flow and a temperature sensor is used to compensate for changes in gas temperature.
Specifications
Flow Measurement: Range — 0 - 1.5 L/s BTPS
Accuracy — 3.5% of reading at BTPS
Weight: 180 grams
Dimensions: 182 mm x 64 mm x 53 mm
Operating Temp: 0 to 50 °C
|
| Liquid Sampling |
| Part Number |
Item |
|
| CASM 03296-02 |
Purge System |
|
| |
Custom Purge System with Condenser and Heating Jacket. Includes purge vessel, filter line with IFD filter, NaOH trap, Teflon tubing and fittings. For analysis of nitric oxide, nitrite, nitrate and nitrosothiols in biological samples such as plasma, cell culture media, or tissue homogenates. |
| CASM 03297-01 |
Large Volume Purge System |
|
| |
Designed for measurement of larger volume samples (> 100 μL), the Large Volume Purge System has about twice the volume of the original purge system and permits measurements of nanomolar levels of NO and its reaction products without the need to frequently change the reagent. Current users of the original purge system can upgrade to the larger volume system by purchasing the large purge vessel glassware only (CASM 03293-01). |
| ASK 14300 |
Liquid Supplies Kit |
|
| |
This kit includes all of the accessories for liquid measurements including ring stand, clamps, syringes, pipettes, filter paper, and sample tubes and rack.
|
| CASK 14500 |
Nitrite Chemicals Kit |
|
| |
All the chemicals for nitrite measurement including sodium iodide, acetic acid, and sodium nitrite. |
| CASK 14400 |
Nitrate Chemicals Kit |
|
| |
All of the chemicals for nitrate measurement including VCl3, 1M HCl, 1N NaOH, and sodium nitrate. |
| Gas Sampling |
| Part Number |
Item |
| CASM 03300-02 |
Gas Sampling Interface |
|
| |
For gas-phase calibration of the NOA and measurement of gas-phase samples. The kit includes a Nafion drier, 0.45 µm particle filter, Teflon sampling line with luer adapters, luer plug, and a calibration tee. |
| CNDK 01400 |
ENO Calibration Gas |
|
| |
Calibration of the NOA for gas-phase measurements is easily performed using this lightweight, disposable cylinder of 45 ppm NO in N2. |
| CACT 01400 |
Zero Air Filter |
|
| |
Calibration of the NOA for gas measurement also requires a gas contains low levels (< 1 ppb) of NO. This is easily produced from room air using a cartridge containing KMnO4 and activated carbon. The trap has sufficient capacity for several years of use. |
| CNCK 01400 |
Calibration Kit |
|
| |
Includes the Zero Air Filter, ENO Calibration gas cylinder, a low flow regulator preset to 300 mL/min gas and a calibration tee. |
For flere detaljer og pris, kontakt venligst MD Scientific via e-mail: info@md-scientific.dk eller telefon: 7027 8565.