Exhaled Breath Sample Applications

The NOA 280i can be used to measure exhaled NO using a wide range of techniques including On-line, Off-Line, Nasal, Breath-by-Breath and Chamber Sampling. The NOA and its accessories permit measurements according to the American Thoracic Society recommendations and other research applications.
  NOA
   

accurate NO breath kit
Accurate NO breath kit

 

 

 

  • It is possible to use the Sievers patented restricted exhaled breath technique, both on-line and off-line sampling
  • Patented restricted exhaled breath technique
  • User defined flow rates for specific research investigations
  • Biofeedback mechanism for reproducible breath flow rates
  • Breath by breath analysis with fast response time
  • Off-line breath analysis performed remotely with reusable bags
  • Off-line breath sample stable for up to 12 hours after collection
  • High sensitivity <1ppb
  • Fast response time - 200ms
  • Data collection with menu based PC or MAC software with statistical results output with export facility for further analysis
  • Low cost maintenance for analyser

 

off-line collection kit
 
Off-line collection kit
 

 

On-Line Sampling
Use our patented* technique and the On-Line NO Breath Kit™ to measure on-line concentrations of NO in exhaled breath without nasal contamination. The NOA 280i's built-in exhaled pressure feedback system and optional Thermal Mass Flowmeter facilitate exhalation at constant flow rates from 10–1000 mL/s. The NOAnalysis REB program is used for flow meter calibration or restrictor selection, data collection and processing.

Off-Line Sampling
Our patented technique and Bag Collection and Sampling Kits permit collection of exhaled breath for later analysis. Two kits are available: Vital Capacity Kit for collection of exhaled breath at 350 mL/s (ATS recommendation) and the Deadspace Discard Kit that permits collection of exhaled breath under that same conditions as on-line measurements. The concentration of NO in the Mylar® bags is stable for 8 to 12 hours and the bags can be reused after a simple cleaning procedure. The NOAnalysis Bag program is used for analysis of the samples.

Nasal Sampling
Use a constant transnasal flow of 3 L/min, with sidestream sampling and a slow oral exhalation against a resistance to measure nasal NO. The NOAanalysis REB program can be used for nasal measurements.

Breath-by-Breath Measurement
Use this technique to measure exhaled NO in subjects who cannot perform the on-line or off-line maneuvers (i.e., ventilated subjects, small children, animals) The NOA 280i's exhalation pressure transducer, and the NOAnalysis Breath program, determine the beginning and end of each exhalation and the concentration of NO for each breath.

Chamber Sampling
The concentration of exhaled NO in spontaneously breathing small animals can be measured using the Chamber Sampling method. Using head-out or whole body plethysmographs, permits exhaled breath to accumulate in the chamber for subsequent measurement by the NOA.

Other Gas Applications
Use the NOA 280i to measure gas-phase NO directly in the airways during bronchoscopy. The NOA can also be used to monitor NO production from other organs (eye, skin, gums).

* Patents US 5,795,787 6,010,459; CA 2,252,024; AU 719,940 2,400,797

 

Exhaled Breath Accessories