HPLC tilbehør fra
Accessories |
|
|
|
MD Scientific er autoriseret forhandler i Danmark for
Showa Denkos (Shodex) produkter |
Eluent Degassing Device:
DEGASSER® ERC-3115alpha, 3215alpha, 3315alpha, 3415alpha
The new ERC-3000alpha series degasser for HPLC is a very compact high quality unit that comes with all of the safety features that chromatographers expect from the world's premiere manufacturer of eluent degassers. This newest, most advanced series of degassers removes the dissolved gas in HPLC eluents easily and efficiently.
Simply connect the unit in front of the pump to obtain stable chromatograms and reliable pump operation. |
|
|
| |
|
| |
Startside for Shodex kolonner
Kataloger og brochurer |
(Features)
· Pressure senssor and leak monitor assure high safety.
· Dead volume is minimized to 7mL/channel.
· Any pump can be used because differential pressure is low.
· Cntinuous degassing mode helps elurnt preparation for high-sensitivity analysis.
· EMC and LVD compliance, with CE marking
(Principle)
The liquid to be degassed runs through a membrane made of special synthetic resin membrane in a vacuum chamber. Dissolved gas in the liquid passes through the membrane and eliminated from the liquid because of its small molecular size, higher mobility than of the liquid, and higher affinity with the sprecial synthetic resin membrane.

(1) Membrane degasser
(2) Vacuum chamber
(3) Pressure sensor
(4) Control board
(5) Three-way solenoid valve
(6) Vacuum pump
(7) Eluent
(8) Feed pump to outlet
(Specifications)
| Model |
ERC-3115alpha |
ERC-3215alpha |
ERC-3315alpha |
ERC-3415alpha |
| Solvent channels |
1 channel |
2 channels |
3 channels |
4 channels |
Degassing
capacity |
When ion-exchanged water saturated with air at 25-deg-C is put through at a flow rate of 3mL/min,
no observed at the outlet of the apparatus.
(Measured dissolved oxygen level at the outlet: 2ppm at flow rate of 3mL/min) |
| Internal volume |
7mL/channel |
| Max. flow rate |
20mL/min for each channel (Eluent: 25deg-C pure water) |
| External output |
An open connector signal is delivered to the external output signal terminal,
When "PRES" and "LEAK" LEDs light. |
| Dimensions |
71W x 310D x 136H (mm) |
| Power source |
AC 100 to 240 V, 50/60Hz |
Functional
Displays
|
Power On/Off display |
"POWER" LED lights, when the power is supplied. |
Status monitoring
function |
"READY" LED lights, when the internal pressure in the vacuum chamber
is below a predetermined limit. |
Pressure monitoring function |
"PRES" LED lights, when the internal pressurein the vacuum chamber
does not reach a predetermined level within a predetermined time. |
Leak monitor |
"LEAK" LED lights, when the liquid leaks in the apparatus. |
Self cleaning |
The vacuum line is cleaned by air suction. |
Vacuum pump operation
switching function |
NORM.: Controlled operation in normal run
CONT.: Cntinuous operation in case og high degree of degassing degassing |
| Weight |
ca 5.0kg |
ca 5.1kg |
ca 5.4kg |
ca 5.5kg |
For the special solvents, such as fluorinated organic solvents, please contact Shodex or our destributors near you.
DEGASSER® is the registered trademark of E.R.C Co. Ltd.
For flere detaljer og pris, kontakt venligst MD Scientific via e-mail: info@md-scientific.dk eller telefon: 7027 8565.
Top
|