Ion Chromatography
|
Columns by comparison:
| Product |
Size |
Plate number |
| |
(mm) ID x Length |
(TPN/column) |
| IC YS-50 |
4.6 x 125 |
> 5,500 |
| IC YS-G |
4.6 x 10 |
(Guard column) |
| WINE VH-anion 4D |
4.0 x 150 |
> 7,000 |
| WINE VH-anionG 4A |
4.6 x 10 |
(Guard column) |
|
High performance Semi-micro GFC columns: SB400-4E
|
Columns by comparison:
| Product |
Exclusion limit (Pullulan) |
Pore Size (Å) Maximum |
Plate number |
Particle size |
Size |
Max. pressure |
Max. usable flow rate |
| |
|
|
(TPN/column) |
(micron) |
(mm) ID x Length |
(MPa) |
(mL/min) |
| SB401-4E |
1,000 |
40 |
> 5,000 |
10 |
4.6 x 250 |
1.8 |
0.30 |
| SB402.5-4E |
10,000 |
200 |
> 20,000 |
6 |
4.6 x 250 |
8.0 |
0.35 |
| SB403-4E |
100,000 |
800 |
> 20,000 |
6 |
4.6 x 250 |
8.0 |
0.35 |
| SB404-4E |
1,000,000 |
2,000 |
> 20,000 |
7 |
4.6 x 250 |
5.0 |
0.35 |
| SB400G-4A |
(guard) |
- |
- |
7 |
4.6 x 10 |
- |
0.35 |
|
|
Polymer-Based (ODP2 HP)
|
Columns by comparison:
| Product |
Size |
Particle size |
Plate number |
Max. pressure |
Max. usable flow rate |
Temperature range |
pH range |
Pore Size (Å) Average |
| |
(mm) ID x Length |
(micron) |
(TPN/column) |
(MPa) |
(mL/min) |
(°C) |
|
|
| ODP2 HP-4B |
4.6 x 50 |
5 |
> 3.500 |
15 |
1.5 |
20 to 60 |
3 to 12 |
40 |
| ODP2 HP-4D |
4.6 x 150 |
5 |
> 13,000 |
15 |
1.5 |
20 to 60 |
3 to 12 |
|
| ODP2 HP-4E |
4.6 x 250 |
5 |
> 17,000 |
15 |
1.0 |
20 to 60 |
3 to 12 |
|
| ODP2 HPG-4A |
4.6 x 10 |
5 |
(Guard column) |
- |
- |
20 to 60 |
3 to 12 |
|
| ODP2 HP-2B |
2.0 x 50 |
5 |
> 3,000 |
12 |
0.3 |
20 to 60 |
3 to 12 |
40 |
| ODP2 HP-2D |
2.0 x 150 |
5 |
> 7,000 |
15 |
0.3 |
20 to 60 |
3 to 12 |
40 |
| ODP2 HPG-2A |
2.0 x 10 |
5 |
(Guard column) |
- |
- |
20 to 60 |
3 to 12 |
|
|
Gel filtration (Protein, OHpak)
|
Columns by comparison:
| Product |
Size |
Particle size |
Plate number |
Max. pressure |
Exclusion limit (Pullulan) |
Exclusion limit (Proteins) |
Pore Size (Å) Maximum |
| |
(mm) ID x Length |
(micron) |
(TPN/column) |
(MPa) |
|
|
|
| PROTEIN KW402.5-4F |
4.6 x 300 |
3 |
> 35,000 |
10 |
60,000 |
150,000 |
400 |
| PROTEIN KW403-4F |
4.6 x 300 |
3 |
> 35,000 |
10 |
150,000 |
600,000 |
800 |
| PROTEIN KW404-4F |
4.6 x 300 |
5 |
> 25,000 |
10 |
500,000 |
1,000,000 |
1,500 |
| PROTEIN KW405-4F |
4.6 x 300 |
5 |
> 25,000 |
7 |
1,300,000 |
20,000,000 |
2,000 |
| PROTEIN KW400G-4A |
4.6 x 10 |
5 |
- |
- |
(Guard column) |
- |
|
| OHpak SB-807 HQ |
8.0 x 300 |
35 |
> 1,500 |
0.5 |
500,000,000 |
- |
30,000 |
| OHpak SB-807G |
8.0 x 50 |
35 |
- |
- |
(Guard column) |
- |
|
|
GFC columns are suitable for analysis of high molecular weight biological fluids such protein and for molecular weight determination. Shodex added new GFC column named KW400 series. KW400 series is semi-micro type of PROTEIN KW-800 series and KW400 series provides high resolution. The packing material is polymer coated silica as same as KW-800, but particle is smaller than KW-800 series.
|
Conditions for all products:
- Recommended flow rate: < 0.35mL/min
- Max. usable flow rate: 0.5mL/min
- Usable temperature pange: 5 to 45deg-C
- Usable pH range: 3.0 to 7.5
- Usable salt conc. in eluent: 0.1 to 0.3M
- Usable organic solvent concentration: Up to 100% for methanol and acetonitrile.
Ion Exchange chromatography
Columns by comparison:
| Product |
Functional group |
Size |
| |
|
(mm) ID x Length |
| IEC DEAE3N-4T |
DEAE |
4.6 x 35 |
|
For flere detaljer og pris, kontakt venligst MD Scientific via e-mail: info@md-scientific.dk eller telefon: 7027 8565.
Top
|