| A new refractive index (RI) detector series is now available. RI-201 is a highly sensitive RI detector incorporating a three-chamber flow cell. |
 |
|
-
(Features
-
A nobel optical system (three-chamber flow cwll) provides twice or better sensitivity than of our previous detectors.
-
The two-step temperature control method significantly reduces drift due to the flucturation of room temperature.
-
The detection limit for saccharides is approximately 2 ng
-
-
Reasonable price
|
| |
|
Catalogue |
|
| |
|
|
Application

|
. Specifications
| Product code |
F4010105 |
| Model |
RI-201 |
| Analysis |
| Flow cell type |
3 chamber-type |
| Measuring method |
Deflection type |
| Refractive Index range |
1.00 to 1.75 |
| Measuring range |
0.125 to 256 micro-RIU |
| Drift |
0.1micro-RIU/h |
| Linearity range |
300micro-RIU |
| Noise |
1nRIU (response: 1.5sec) |
| Response |
0.1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec |
| Auto zero |
Full auto zero |
| Auto zero range |
All range |
| Off-set range |
5micro-RIU |
| Off-set response |
25nRIU |
Integrator output
(Sensitivity) |
DC 0 to 1V
(4mV/micro-RIU, 16mV/micro-RIU) |
| Cell volume |
8micro-L |
| Flow rate |
(Usual) |
0.2 to 3.0mL/min |
| (Max.) |
10mL/min (solvent: pure water) |
| Max. back pressure |
50kPa |
| Internal volume |
IN to Cell: ca. 80micro-L
Cell to OUT: ca. 600micro-L
All(Cell to OUT: ca.690micro-L |
| Recorder output |
0 to 10mV/FS |
| EXternal input |
- |
| EXternal output |
(1) READY (temperature control)
(2) LEAK
(3) ERROR (ROM, RAM, PARAMETER, HOME POSITION, OVER-HEAT,
OPTI.-BALANCE, INTENSITY) |
| Temp. control |
OFF, 30 to 50deg-C (1deg-C step), 77deg-C Temp. fuse |
| Communication port |
USB |
Operational support
functions |
None |
| Wetted materials |
Stainless steel 316, Teflon, Quartz glass |
Power source,
Power consumption |
AC 100 to 240V±10%, 50/60Hz, 150VA max. |
| Demensions, Weight |
W260 x D400 x H150 (mm), ca.12kg |
| Accessories |
Power cable, single code, connector tube, fuse, operation manual |
RI-201H
Model |
RI-201H |
| Analysis |
Flow cell type |
2 chamber-type |
Measuring method |
Deflection type |
| Refractive Index range |
1.00 to 1.75 |
Measuring range |
0.25 to 512 micro-RIU |
Drift |
0.2micro-RIU/h |
| Linearity range |
600micro-RIU |
Noise |
2.5nRIU (response: 1.5sec) |
Response |
0.1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec |
Auto zero |
Full auto zero |
Auto zero range |
All range |
Off-set range |
10micro-RIU |
Off-set response |
50nRIU |
Integrator output
(Sensitivity) |
DC 0 to 1V
(2mV/micro-RIU, 8mV/micro-RIU) |
Cell volume |
8micro-L |
Flow rate |
(Usual) |
0.2 to 3.0mL/min |
(Max.) |
10mL/min (solvent: pure water) |
Max. back pressure |
50kPa |
Internal volume |
IN to Cell: ca. 60micro-L
Cell to OUT: ca. 600micro-L
All(Cell to OUT: ca.670micro-L |
Recorder output |
0 to 10mV/FS |
EXternal input |
- |
EXternal output |
(1) READY (temperature control)
(2) LEAK
(3) ERROR (ROM, RAM, PARAMETER, HOME POSITION, OVER-HEAT,
OPTI.-BALANCE, INTENSITY) |
Temp. control |
OFF, 30 to 50deg-C (1deg-C step), 77deg-C Temp. fuse |
Communication port |
USB |
Operational support
functions |
None |
Wetted materials |
Stainless steel 316, Teflon, Quarts glass |
Power source,
Power consumption |
AC 100 to 240V±10%, 50/60Hz, 150VA max. |
Demensions, Weight |
W260 x D400 x H150 (mm), ca.12kg |
Accessories |
Power cable, single code, connector tube, fuse, operation manual |
For flere detaljer og pris, kontakt venligst MD Scientific via e-mail: info@md-scientific.dk eller telefon: 7027 8565.