|
|
Thermo Fisher Scientific offers a range of quality syringes designed by chromatographers with high accuracy and precision to ensure expected volumes are delivered.
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
Thermo Fisher Scientific syringes are well-suited for use with other manufacturer's instruments.
A range of high quality syringes for Thermo Scientific autosamplers and instruments.
Gas tight syringes are suitable for both liquid and gaseous samples.
High-quality Thermo Fisher Scientific syringes designed for manual GC injections.
Extend the life and performance of you Plunger in Needle syringes with Repair Kits.
Thermo Fisher Scientific offers replacement needles for syringes with removable needles.
Replacement plungers are available for Thermo Fisher Scientific gas tight syringes. |
|
|
| |
|
|
| Top |
|
|
GC Autosampler Syringes for Other Instruments
Accurate and robust, the Thermo Fisher Scientific syringes suit other leading manufacturers’ instruments and autosmapler. They incorporate design features that make them easy-to-use, enhancing the repeatability of injection and the reliability of results.
The result of any GC analysis is dependent upon the accuracy and precision of the syringe used to transfer the sample into the GC. Thermo Fisher Scientific’s syringes are designed, manufactured and inspected to ensure the expected volume is transferred every time. Our syringes are made by chromatographers who are familiar with the requirements of the entire GC system, not just syringe manufacturing. These syringes include fixed and removable needles as well as standard and gas-tight plungers for your convenience.
- One source for all GC models
- Agilent 7673, 7683 and 6850
- PerkinElmer Autosystem and Clarus® 500
- Shimadzu AOC 14, 17, 20 and 20i
- Varian 8035, 8100, 8200 and 8400
- Teflon® Tipped plungers - Prevents plunger binding with dirty samples
- Cone point needle tip - Optimized for septum piercing
- Field proven designs
Syringe Specifications
Temperature Limits:
- 5– 115°C for removable needle syringes
- 5– 70°C for fixed needle syringes
Volume Specifications:
- Accuracy ±1% (±2% for plunger-in-needle syringes)
- Reproducibility (displaced volume) ±1% (±2% for plunger-in-needle syringes)
Maximum Safe Working Pressure:
- 5 µL to 100 µL – 1000 psi, 250 µL and 500 µL – 500 psi
- 1 mL to 5 mL – 400 psi, 10 mL – 200 psi
- 25 mL, 50 mL and 100 mL – 100 psi
- Maximum Functional Pressure: 100 psi
Materials Used:
- Gas tight plunger tips – PTFE
- Metal plungers – stainless steel
- Glass – borosilicate
- Metal flanges – stainless steel; nickel plated brass
- Needles – stainless steel
| GC Autosampler Syringes for Other Instruments |
| Product# |
Manufacturer |
Volume |
Needle |
Gauge |
Tip |
|
| |
|
|
|
|
|
|
| 365A0411 |
Agilent |
0.5 µL |
RN, 42 mm |
26 |
cone |
|
| 365C0921 |
Agilent |
5 µL |
FN, 42 mm |
26 |
cone |
| 365C0951 |
Agilent |
5 µL |
FN, 42 mm |
26 |
cone |
| 365D1521 |
Agilent |
10 µL |
FN, 42 mm |
26 |
cone |
| 365D1561 |
Agilent |
10 µL |
FN, GT, 42 mm |
23-26 |
cone |
| 365A0471 |
PE |
0.5 µL |
RN, 70 mm |
26 |
cone |
| 365C1021 |
PE |
5 µL |
FN, 70 mm |
23 |
cone |
| 365D1771 |
Shimadzu |
10 µL |
RN, 42 mm |
26 |
cone |
| 365D1811 |
Varian |
10 µL |
RN, 53 mm |
25 |
side hole |
| 365D1831 |
Varian |
10 µL |
FN, 50 mm |
26 |
bevel |
|
Top
GC Syringes for Thermo Scientific Instruments
Accurate and robust, the Thermo Scientific syringes for Thermo Scientific GC instruments and autosamplers incorporate design features that make them easy-to-use, enhancing the repeatability of injection and the reliability of results. These syringes include fixed and removable needles as well as standard and gas tight plungers for your convenience.
Syringe Specifications
Temperature Limits:
- 5– 115°C for removable needle syringes
- 5– 70°C for fixed needle syringes
Volume Specifications:
- Accuracy ±1% (±2% for plunger-in-needle syringes)
- Reproducibility (displaced volume) ±1% (±2% for plunger-in-needle syringes)
Maximum Safe Working Pressure:
- 5 µL to 100 µL – 1000 psi, 250 µL and 500 µL – 500 psi
- 1 mL to 5 mL – 400 psi, 10 mL – 200 psi
- 25 mL, 50 mL and 100 mL – 100 psi
- Maximum Functional Pressure: 100 psi
Materials Used:
- Gas tight plunger tips – PTFE
- Metal plungers – stainless steel
- Glass – borosilicate
- Metal flanges – stainless steel; nickel plated brass
- Needles – stainless steel
Please refer to the table below to choose the best syringe for your instrument and application:
- TriPlusTM, AS3000, AS2000, AS200 and AS800
- Teflon® Tipped plungers - Prevents plunger binding with dirty samples
- Cone point needle tip - Optimized for septum piercing
| NEEDLE |
LENGTH |
GAUGE |
TIP |
PART NO. |
TRIPLUS |
AS 3000 |
AS 2000 |
AS200 AS800 |
NOTES |
Plunger- in-Needle |
50 mm |
23 |
Cone |
36504045 |
X |
X |
|
|
Split/PTV |
| Plunger- in-Needle |
75 mm |
31 |
Cone |
36500500 |
|
|
|
|
Manual OC |
| Plunger- in-Needle |
80 mm |
26 |
Cone |
36504046 |
X |
X |
|
|
|
| Fixed Needle |
50 mm |
26 |
Cone |
36504047 |
X |
|
|
|
Split/PTV |
| Fixed Needle |
50 mm |
23 |
Cone |
365C3701 |
|
X |
X |
X |
|
| Fixed Needle |
50 mm |
26 |
Cone |
36500505 |
|
X |
X |
|
Split/PTV |
| Removable Needle |
75 mm |
31 |
Cone |
36500510 |
|
|
|
|
Manual OC |
| Removable Needle |
42 mm |
23 |
Cone |
365D1611 |
|
|
|
X |
|
| Fixed Needle |
50 mm |
26 |
Cone |
365D1856 |
X |
X |
X |
X |
|
| Fixed Needle |
50 mm |
25 |
Cone |
36500525 |
X |
X |
X |
X |
Split/PTV |
| Fixed Needle |
50 mm |
23 |
Cone |
36520060 |
X |
X |
X |
X |
BEST PTV/SSL Split |
| Removable Needle |
50 mm |
26 |
Cone |
365D1841 |
X |
X |
X |
|
|
| Removable Needle |
50 mm |
23 |
Cone |
365D3731 |
X |
X |
X |
X |
|
| Fixed Needle |
80 mm |
23 |
Cone |
36520061 |
X |
|
X |
|
Merlin V |
| Fixed Needle |
50 mm |
23–26 |
Cone |
36500580 |
X |
|
X |
|
OC in PTV Merlin Valve |
Fixed Needle, Gas Tight |
50 mm |
23 |
Cone |
365D3741 |
X |
|
X |
|
|
| Fixed Needle |
80 mm |
26 |
Cone |
36502019 |
X |
|
X |
|
OC & Splitless |
| Removable Needle, Gas Tight |
75 mm |
31 |
Cone |
36500520 |
|
|
|
|
Manual OC |
| Removable Needle, Gas Tight |
50 mm |
25 |
Bevel |
365G2161 |
|
|
|
X |
|
| Removable Needle |
50 mm |
23 |
Cone |
36503015 |
|
|
X |
|
LV Splitless |
| Removable Needle |
50 mm |
25 |
Bevel |
365H2301 |
|
|
|
X |
|
| Removable Needle, Gas Tight |
50 mm |
23 |
Side Hole |
36520050 |
X |
|
X |
|
|
| Removable Needle, Gas Tight |
50 mm |
25 |
Bevel |
365H2381 |
|
|
|
X |
|
| Removable Needle, Gas Tight |
50 mm |
23 |
Cone |
36500495 |
X |
|
X |
X |
LV Splitless |
| Removable Needle, Gas Tight |
50 mm |
25 |
Bevel |
365I2561 |
|
|
|
X |
|
| Removable Needle, Gas Tight |
50 mm |
25 |
Bevel |
365I2611 |
|
|
|
X |
|
| Removable Needle, Gas Tight |
80 mm |
26 |
Cone |
36500490 |
X |
|
X |
|
LVOC |
| Removable Needle, Gas Tight |
50 mm |
23 |
Side Hole |
36520051 |
X |
|
X |
X |
See note 1 |
| Removable Needle, Gas Tight |
50 mm |
23 |
Bevel |
365K3041 |
|
|
|
X |
|
| 1. Specific syringe to be used when performing PTV/LVI injections with dedicated liner for Thermo Scientific labile compounds (p/n 45302060). Compatible with Merlin Microseal™ device installed on BEST PTV (kit p/n 19050205) and with AS2000 and TriPlus autosamplers for liquids. |
| GC Syringes for Thermo Scientific Instruments |
| Product# |
Price |
Volume |
Needle Type |
Needle Length |
Needle Gauge |
Tip Style |
| |
|
|
|
|
|
|
| 36504046 |
- |
0.5 µL |
PIN |
80 mm |
26 |
cone |
| 365C3701 |
- |
5.0 µL |
FN |
50 mm |
23 |
cone |
| 36500510 |
- |
5.0 µL |
RN |
75 mm |
31 |
cone |
| 365D1611 |
- |
10 µL |
RN |
42 mm |
23 |
cone |
| 365D1856 |
- |
10 µL |
FN |
50 mm |
26 |
cone |
| 365D1841 |
- |
10 µL |
RN |
50 mm |
26 |
cone |
| 365D3731 |
- |
10 µL |
RN |
50 mm |
23 |
cone |
| 365D3741 |
- |
10 µL |
FN, GT |
50 mm |
23 |
cone |
| 36500520 |
- |
10 µL |
RN, GT |
75 mm |
31 |
cone |
| 36503015 |
- |
50 µL |
RN |
50 mm |
23 |
cone |
Top
The Thermo Fisher Scientific range of gas tight syringes feature a replaceable Teflon® tip plunger, making them ideal for use with liquid or gas samples. Gas tight syringes are also available for use with Thermo Fisher Scientific and other manufacturer's autosamplers.
Syringe Selection:
- Zero dead volume syringes – 0.5 µL and 1 µL
- Standard plungers – 5 µL to 500 µL
- Gas tight plungers – 10 µL to 1 mL
- Fixed needles – 5 µL to 1 mL
- Removable needles – 5 µL to 1
Thermo Fisher Scientific offers a wide range of syringes to meet your needs:
- Teflon® PFTE tip replaceable plunger - to give gas tight seal
- Borosilicate Glass - inert to GC solvents and organics
- Stainless Steel - inert and non-reactive
- Industry Standard Size - consistent syringe fit
- Permanent Scale Markings - solvents won’t wash off the markings
- White Scale Backing - easy-to-read improves reproducibility
Syringe Specifications
Temperature Limits:
- 5– 115°C for removable needle syringes
- 5– 70°C for fixed needle syringes
Volume Specifications:
- Accuracy ±1%
- Reproducibility (displaced volume) ±1%
- Maximum Safe Working Pressure: 5 µL to 100 µL – 1000 psi; 250 µL and 500 µL – 500 psi; 1 mL to 5 mL – 400 psi;
- Maximum Functional Pressure: 100 psi
Materials Used:
- Gas tight plunger tips – PTFE
- Glass – borosilicate
- Metal flanges – stainless steel; nickel plated brass
- Needles – stainless steel
| Product# |
Volume |
Needle |
Gauge |
Tip |
| |
|
|
|
|
| 365F1921 |
25 µL |
FN, GT, 50 mm |
25 |
bevel |
| 365F1931 |
25 µL |
RN, GT, 70 mm |
25 |
bevel |
| 365G2111 |
50 µL |
FN, GT, 50 mm |
25 |
bevel |
| 365G2161 |
50 µL |
RN, GT, 50 mm |
25 |
bevel |
| 365H2321 |
100 µL |
FN, GT, 50 mm |
25 |
bevel |
| 365H2381 |
100 µL |
RN, GT, 50 mm |
25 |
bevel |
| 365I2561 |
250 µL |
FN, GT, 50 mm |
25 |
bevel |
| 365I2611 |
250 µL |
RN, GT, 50 mm |
25 |
bevel |
| 365J2831 |
500 µL |
FN, GT, 50 mm |
25 |
bevel |
| 365J2881 |
500 µL |
RN, GT, 50 mm |
25 |
- |
| 365K3041 |
1.0 mL |
RN, GT, 50 mm |
23 |
bevel |
| 365K3051 |
1.0 mL |
FN, GT, 50 mm |
22 |
bevel |
Top
High-quality Thermo Fisher Scientific syringes designed for manual GC injections.
Syringe Selection:
- Zero dead volume syringes – 0.5 µL and 1 µL
- Standard plungers – 5 µL to 500 µL
- Gas tight plungers – 10 µL to 1 mL
- Fixed needles – 5 µL to 1 mL
- Removable needles – 5 µL to 1
Thermo Fisher Scientific offers a wide range of syringes to meet your needs:
- Borosilicate Glass - inert to GC solvents and organics
- Stainless Steel - inert and non-reactive
- Industry Standard Size - consistent syringe fit
- Metal Flange - protect glass barrel from breakage
- Permanent Scale Markings - solvents won’t wash off the markings
- 0.5 µL to 1 mL Volumes - wide range for ideal sample take up and delivery
- Plunger Protection - prevents plunger bending incidences
- White Scale Backing - easy-to-read improves reproducibility
Syringe Specifications
Temperature Limits:
- 5– 115°C for removable needle syringes
- 5– 70°C for fixed needle syringes
Volume Specifications:
- Accuracy ±1% (±2% for plunger-in-needle syringes)
- Reproducibility (displaced volume) ±1% (±2% for plunger-in-needle syringes)
Maximum Safe Working Pressure:
- 5 µL to 100 µL – 1000 psi
- 250 µL and 500 µL – 500 psi
- 1 mL to 5 mL – 400 psi10 mL – 200 psi
- 25 mL, 50 mL and 100 mL – 100 psi
- Maximum Functional Pressure: 100 psi
Materials Used:
- Metal plungers – stainless steel
- Glass – borosilicate
- Metal flanges – stainless steel; nickel plated brass
- Needles – stainless steel
| Product# |
Volume |
Needle |
Gauge |
Tip |
| |
|
|
|
|
| 365A0331 |
0.5 µL |
PIN, 50 mm |
23 |
cone |
| 365B0511 |
1.0 µL |
PIN, 50 mm |
23 |
cone |
| 365B0531 |
1.0 µL |
PIN, 70 mm |
23 |
cone |
| 365C0741 |
5.0 µL |
FN, 50 mm |
26 |
bevel |
| 365C0761 |
5.0 µL |
RN, 50 mm |
26 |
bevel |
| 365D1091 |
10 µL |
FN, 50 mm |
26 |
bevel |
| 365D1096 |
Pk 6 10 µL |
FN, 50 mm |
26 |
bevel |
| 365D1171 |
10 µL |
RN, 50 mm |
26 |
bevel |
| 365F1891 |
25 µL |
FN, 50 mm |
25 |
bevel |
| 365F1901 |
25 µL |
RN, 50 mm |
25 |
bevel |
| 365G2081 |
50 µL |
FN, 50 mm |
25 |
bevel |
| 365G2091 |
50 µL |
RN, 50 mm |
25 |
bevel |
| 365H2291 |
100 µL |
FN, 50 mm |
25 |
bevel |
| 365H2301 |
100 µL |
RN, 50 mm |
25 |
bevel |
| 365I2541 |
250 µL |
FN, 50 mm |
25 |
bevel |
Top
Repair Kits for PIN Syringes
Extend the life and performance and reduce cost per use of you Plunger in Needle syringes with Repair Kits from Thermo Fisher Scientific.
Repair kits for Plunger in Needle syringes contain both the plunger and needle, which must be changed together. The kits consists of one of each.
| Repair Kits for PIN Syringes |
| Product# |
For Syringe |
| |
|
| 365RK541 |
365A0411 |
| 365RK241 |
365A0421 |
| 365RK261 |
365A0431 |
| 365RK291 |
365A0471 |
| 365RK331 |
365A0481 |
| 365RK321 |
365A0331 |
| 365RK311 |
365B0511 |
| 365RK341 |
365B0531 |
Replacement Syringe Needles
Thermo Fisher Scientific offers replacement needles for syringes with removable needles.
| Replacement Syringe Needles |
| Product# |
For Syringe # |
Quantity |
| |
|
|
| 365RN252 |
365D1611 |
2 |
| 365RN362 |
365D1841 |
2 |
| 365RN272 |
365D1771 |
2 |
| 365RN372 |
365D3731 |
2 |
| 365RN225 |
365H2301, 365F1931, 365G2161, 365H2381, 365I2611, 365F1901, 365G2091, 365J2881 |
5 |
| 365RN235 |
365K3041 |
5 |
| 36566480 |
36500490 |
1 |
| 365RN351 |
365D1811 |
1 |
| 365RN555 |
365C0761 |
5 |
| 365RN215 |
365D1171 |
5 |
Replacement Syringe Plungers
Replacement plungers are available for Thermo Fisher Scientific gas tight syringes.
| Replacement Syringe Plungers |
| Product# |
For Syringe # |
Quantity |
| |
|
|
| 365RP421 |
365F1920, 365F1931 |
1 |
| 365RP451 |
365G2111, 365G2161 |
1 |
| 365RP461 |
365H2321, 365H2381 |
1 |
| 365RP481 |
365I2561, 365I2611 |
1 |
| 365RP491 |
365J2831, 365J2881 |
1 |
| 365RP511 |
365K3041, 365K3051 |
1 |
| 365RP392 |
365D1561 |
2 |
| 365RP382 |
365C1041, 365C1031 |
2 |
| 365RP522 |
365D1791 |
2 |
| 365RP532 |
365D3741 |
2 |
| 365RP412 |
365D1611 |
2 |
| 365RP471 |
365H3771 |
1 |
For flere detaljer og pris, kontakt venligst MD Scientific via e-mail: info@md-scientific.dk eller telefon: 7027 8565.
Top
|