TSK-GEL® kolonner
Reversed Phase Chromatography
Silica-based Reversed Phase Columns
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
The silica-based TSK-GEL reversed phase product line consists of eleven stationary phases designed for the analysis of low molecular weight analytes such as:
- pharmaceutical drugs
- forensic compounds
- derivatized amino acids
- carbohydrates
- steroids, lipids, fatty acids
Depending on their molecular weight, peptides may be analyzed with the same silica-based RPC columns, while proteins require a larger pore size column (200-300 angstrom ).
TSK-GEL silica packings are spherical with uniform pore sizes of 100, 140, 150, or 250 angstrom bonded with a monomeric or polymeric layer of octadecyl, octyl, cyano, trimethylsilyl or phenyl groups. Several of the stationary phases are subsequently capped with trimethylsilyl groups by a proprietary method that deactivates the unreacted but accessible silanol groups.
100Å Monomeric
RP Silica |
80Å Monomeric
RP Silica |
2µm Super Series
RP Silica |
Specialty
RP Silica |
This latest generation of highly pure 100Å pore size silica is the foundation for sophisticated bonding chemistries.
These are the preferred columns for demanding separations of polar (ODS-100V) and small MW basic compounds (ODS-100Z).
|
The 100Å pore size makes this column type ideal for samples smaller than 6,000 Da molecular weight. This product line features exhaustively endcapped 80Ts columns for basic solutes and the moderately endcapped 80Tm columns for peptide separations.
|
The “Super Series” provides higher efficiency and improved resolution over conventional columns packed with 3 and 5μm particles.
Pore size of 140Å makes the “Super Series” columns most suitable for samples with molecular weight below 10,000 Da molecular weight.
|
|
TSK-GEL specialty RP silica columns were developed to provide optimum separation for:
|
|
80Å Pore Size Monomeric RP Silica
For analysis of small molecules, the 100Å pore size, 5 micron particle size 80Tm and 80Ts columns are offered in 4 different chemistries to suit a variety of needs.
The Type B base silica is of high purity and contains few metal ion impurities. Combined with monomeric bonding chemistry, these reveresed phase columns have an established reputation as general purpose columns for pharmaceutical applications.
The monomeric materials are delineated by the following nomenclature:
- Bonded phase pore size is indicated by the number in the product description, for instance, ODS-80Ts has 80Å nominal pore size. The pore size of the base silica is 100Å.
- T denotes an endcapped phase.
- M, as in 80Tm, indicates that a regular endcapping Rx has been performed.
- S, as in 80Ts, indicates a more exhaustive endcapping Rx has been performed.
- QA in ODS-80Ts QA indicates maximum lo-to-lot reproducibility of retention and selectivity
|
Highlights
-
Spherical silica with 100Å pores allows fast mass transfer of solutes in the 100 to 6,000Da MW range.
-
Silica surface has low metal content.
-
Monomeric-bonded phase chemistry for optimal lot-to-lot reproducibility.
-
The subscript 'm' indicates that the material has been endcapped. The 's' subscript denotes a more exhaustive endcapping reaction to shield the silica surface to interact with charged solutes.
-
Available in particle sizes of 5µm,10µm, and 20µm.
-
Large surface area and high sample capacity.
-
General purpose Reversed Phase columns.
|
|
|
|
|
General purpose column for:
- drug analysis,
- basic compounds,
- nucleic acid fragments
|
Complete endcapping makes the TSKgel ODS-80Ts the column of choice for strongly basic compounds and for applications that require operation at pH 7.5. |
Faster kinetics than ODS, but lower hydrophobic selectivity. |
Alternative to ODS and Octyl for analysis of polar compounds |
|
|
TSKgel ODS-80Tm
TSKgel ODS-80Tm is a general purpose column for the analysis of low MW pharmaceuticals, bases, nucleosides and nucleotides. Common applications include purity checks and peptide mapping.
Bonded phase pore size is indicated by the number in the product description, in this case TSKgel ODS-80Tm has 80Å nominal pore size. The pore size of the base silica is 100Å.
|
Structure:

Product Attributes:
| Pore size (silica): |
100Å |
| Molecular Weight Limit: |
6,000Da |
| Endcapped: |
yes |
| Particle size (mean): |
5µm and 10µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C18 (monomeric bonding chemistry) |
| % carbon |
15% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
|
Applications |
Peptide analysis on TSKgel ODS-80Tm

Common pharmaceuticals on TSKgel ODS-80Tm

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
16651 |
TSKgel ODS-80Tm |
|
Stainless Steel |
4.6 |
7.5 |
08148 |
TSKgel ODS-80Tm |
5μm |
Stainless Steel |
4.6 |
15 |
08149 |
TSKgel ODS-80Tm |
5μm |
Stainless Steel |
4.6 |
25 |
|
Guard Cartridge for 4.6mm ID columns, Replaces P/N 17242, 3 pk |
|
Stainless Steel |
3.2 |
1.5 |
19018 |
Guard Cartridge Holder for P/N 19004, Replaces P/N 14100 |
|
Stainless Steel |
3.2 |
1.5 |
|
TSKgel ODS-80Tm |
|
Stainless Steel |
21.5 |
30 |
|
Guard Column for P/N 14002 |
|
Stainless Steel |
21.5 |
7.5 |
|
|
TSKgel ODS-80Ts
TSKgel ODS-80Ts is a general purpose column for low MW pharmaceuticals, bases, nucleosides and nucleotides. Common applications include purity checks and peptide mapping.
Bonded phase pore size is indicated by the number in the product description, in this case TSKgel ODS-80Ts has 80Å nominal pore size. The pore size of the base silica is 100Å.
|
Structure:

Product Attributes:
| Pore size (silica): |
100Å |
| Molecular Weight Limit: |
6,000Da |
| Endcapped: |
yes |
| Particle size (mean): |
5µm and 10µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C18 (monomeric bonding chemistry) |
| % carbon |
15% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
Separation Report -- Application of TSK-GEL Semi-Micro Columns for High-Sensitivity Analyses
|
Applications |
Separation of eighteen PTC-derivatized amino acids

Separation of pharmaceuticals on narrow bore TSKgel-80Ts column.

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
18150 |
TSKgel ODS-80Ts |
5 |
Stainless Steel |
2 |
15 |
18151 |
TSKgel ODS-80Ts |
5 |
Stainless Steel |
2 |
25 |
19325 |
Guard Cartridge for 2mm ID columns, 3 pk |
|
Stainless Steel |
2 |
1 |
|
Guard Cartridge Holder for P/N 19325 |
|
Stainless Steel |
2 |
1 |
17200 |
TSKgel ODS-80Ts |
|
Stainless Steel |
4.6 |
7.5 |
|
TSKgel ODS-80Ts |
|
Stainless Steel |
4.6 |
15 |
17202 |
TSKgel ODS-80Ts |
5 |
Stainless Steel |
4.6 |
25 |
|
Guard Cartridge for 4.6mm ID columns, 3 pk, Replaces P/N 17242 |
|
Stainless Steel |
3.2 |
1.5 |
|
Guard Cartridge Holder for P/N 19011, Replaces P/N 14100 |
|
Stainless Steel |
3.2 |
1.5 |
|
TSKgel ODS-80Ts |
|
Stainless Steel |
21.5 |
30 |
|
Guard Column for P/N 17380 |
|
Stainless Steel |
21.5 |
7.5 |
|
|
TSKgel CN-80Ts
TSKgel CN-80Ts is an alternative to C18 (ODS) and C8 (Octyl) phases. The cyano group is the least hydrophobic of the 100Å phases available and in some cases is used under normal phase conditions. The chromatograms below show retention and selectivity of TSKgel CN-80Ts for 3 aromatic hydrocarbon compounds.
Bonded phase pore size is indicated by the number in the product description, in this case TSKgel CN-80Ts has 80Å nominal pore size. The pore size of the base silica is 100Å.
CN-80Ts is useful for the analysis of polar peptides, amino acids, and other pharmaceutical and food & beverage products. As with other 80Ts products, TSKgel CN-80Ts provides reproducible separations of molecules below 6,000 MW.
|
Structure:

Product Attributes:
| Pore size (silica): |
100Å |
| Molecular Weight Limit |
6,000Da |
| Endcapped: |
yes-complete |
| Particle size: |
5μm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
Cyano (monomeric bonding chemistry) |
| % carbon |
8% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
|
Application |
Aromatic compounds on TSKgel CN-80Ts

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
17348 |
TSKgel CN-80Ts |
5μm |
Stainless Steel |
4.6 |
15 |
17349 |
TSKgel CN-80Ts |
5μm |
Stainless Steel |
4.6 |
25 |
19013 |
Guard Cartridge for 4.6mm ID columns, Replaces P/N 17379, 3 pk |
5μm |
Stainless Steel |
3.2 |
1.5 |
19018 |
Guard Cartridge Holder for P/N 19013, Replaces P/N 14100 |
|
Stainless Steel |
3.2 |
1.5 |
|
|
TSKgel Octyl-80Ts
TSKgel Octyl-80Ts has a lower carbon load and hydrophobicity than the corresponding ODS products. The C8 alkyl ligand provides a unique selectivity for the analysis of low MW pharmaceuticals, bases, nucleosides and nucleotides. Featuring high purity, metal free silica and a proprietary technique for complete endcapping of residual silanol groups, TSKgel Octyl-80Ts columns reduce tailing when analyzing basic compounds. Common applications include purity checks and peptide mapping.
Bonded phase pore size is indicated by the number in the product description, in this case TSKgel Octyl-80Ts has 80Å nominal pore size. The pore size of the base silica is 100Å.
|
Structure:

Product Attributes:
| Pore size (silica): |
100Å |
| Molecular Weight Limit: |
6,000Da |
| Endcapped: |
yes-exhaustive |
| Particle size (mean): |
5µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C8 (monomeric bonding chemistry) |
| % carbon |
11% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
|
Applications |
Aromatic compounds on TSKgel Octyl-80Ts

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
17344 |
TSKgel Octyl(C8)-80Ts |
5μm |
Stainless Steel |
4.6 |
15 |
17345 |
TSKgel Octyl(C8)-80Ts |
|
Stainless Steel |
4.6 |
25 |
19012 |
Guard Cartridge for 4.6mm ID columns, Replaces P/N 17378, 3 pk |
|
Stainless Steel |
3.2 |
1.5 |
19018 |
Guard Cartridge Holder for P/N 19012, Replaces P/N 14100 |
|
Stainless Steel |
3.2 |
1.5 |
|
|
TSK-GEL ODS-80Ts QA
TSK-GEL ODS-80Ts QA columns were developed specifically for use by QA/QC departments that require highly reproducible separations. These columns are prepared from the same endcapped C18 packing material as TSK-GEL ODS-80Ts columns, but with narrower manufacturing specifications to meet the demand for high reproducibility.
The variation between different lots of TSK-GEL ODS-80Ts QA packing material is minimized by selecting batches of TSK-GEL ODS-80Ts that fall within a very narrow range of specifications, as demonstrated in the table below. In addition, each column must pass demanding specifications for efficiency (N) and peak asymmetry, as are spelled out in the Operating Conditions and Specifications sheet. The end result is TSK-GEL ODS-80Ts QA columns that exhibit an unparalleled level of reproducibility for retention, selectivity (k´), efficiency (N), and peak symmetry.
Product Specifications:
Attribute |
Specification Range |
Lot-to-Lot Reproducibility (CV%) |
Particle size:
- Distribution (dp90/dp10) |
4.95 - 5.35
1.55 - 1.70 |
0.6
1.8 |
Surface area (m2/g) |
410 - 440 |
0.5 |
Pore size (mL/g) silica: |
9.0 - 10.0 |
0.5 |
Pore volume (nm):
|
0.96 - 1.04 |
0.7 |
Carbon content (wt%): |
14.0 - 15.0 |
N/A |
C18 coverage (µmol/m2): |
1.71 - 1.99 |
1.3 |
Metal ion content (ppm)
- Na
- Al
- Fe
- Ti |
<10
<10
<10
<10
|
N/A
N/A
N/A
N/A
|
|
Column classification:
TSK-GEL ODS-80Ts QA columns were submitted to several characterization tests to determine the level of hydrophobic retention, steric selectivity and retention of basic compounds. The results of the characterization tests were used to establish specifications listed in the Table below.
Parameter |
|
CV (%) |
Test Conditions |
k' naphthalene (hydrophobicity) |
|
1.3 |
1 |
α triphenylene/o-terphenyl (steric selectivity) |
|
0.4 |
1 |
k' procainamide (basic compounds) |
|
2.6 |
2 |
k' phenol
|
|
0.9 |
2 |
k' oxine copper (inertness to chelating compounds) |
|
3.5 |
3 |
|
1. 80% CH3OH/20% H2O, T=40°C
2. 10% ACN/90% 20mmol/L Na2HPO4 (pH6.6, adjusted with 20mmol/L NaH2PO4, T=40°C)
3. 7% ACN/93% 20mmol/L H3PO4, T=40°C
Application
To demonstrate the lot-to-lot reproducibility that can be expected when using TSK-GEL ODS-80Ts QA columns, the contents of an over-the-counter analgesic pain reliever was analyzed on columns from three different lots of packing material. The results are shown in the Figure to the right and Table below. Excellent reproducibility of retention, peak height, peak area, efficiency and peak shape is evident for all three ingredients. Highly reproducible results can be achieved using the TSK-GEL ODS-80Ts QA columns as shown in this lot-to-lot reproducibility test. |
Analysis of an over-the-counter analgesic
pain reliever

|
|
|
Results
| Compound |
Lot# |
RT (min) |
Peak Area
(mv x sec) |
Peak Height |
N |
AF |
| caffeine |
01W
02W
03W |
3.047
3.080
3.080 |
4.51575 x 102
4.50235 x 102
4.44175 x 102 |
99.26
94.04
95.63 |
10,396
9,597
10,143 |
1.10
1.13
1.13 |
| salicylamide |
01W
02W
03W |
6.190
6.253
6.250 |
3.96172 x 102
3.94822 x 102
3.90617 x 102 |
54.06
52.23
52.40 |
16,441
15,797
16,333 |
1.03
1.07
1.06 |
| acetylsalicylic acid |
01W
02W
03W |
9.983
10.080
10.063 |
4.34473 x 102
4.33835 x 102
4.27633 x 102 |
37.35
36.48
36.28 |
16,742
16,297
16,649 |
1.03
1.05
1.05 |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Operating Conditions and Specifications
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
18768 |
TSKgel ODS-80Ts QA |
5μm |
Stainless Steel |
2 |
15 |
18769 |
TSKgel ODS-80Ts QA |
5μm |
Stainless Steel |
2 |
25 |
18519 |
TSKgel ODS-80Ts QA |
|
Stainless Steel |
4.6 |
7.5 |
18520 |
TSKgel ODS-80Ts QA |
|
Stainless Steel |
4.6 |
15 |
18521 |
TSKgel ODS-80Ts QA |
|
Stainless Steel |
4.6 |
25 |
19325 |
Guard Cartridge for 2mm ID columns, 3 pk |
|
Stainless Steel |
2 |
1 |
19308 |
Guard Cartridge Holder for 2mm ID cartridges |
|
Stainless Steel |
2 |
1 |
19011 |
Guard Cartridge for 4.6mm ID columns, 3 pk |
|
Stainless Steel |
3.2 |
1.5 |
19018 |
Guard Cartridge Holder for 4.6mm ID cartridges |
|
Stainless Steel |
3.2 |
1.5 |
|
100Å Pore Size Monomeric RP Silica
TSKgel ODS-100V and TSKgel ODS-100Z columns incorporate the best-in-class surface properties to limit secondary interactions of basic, acidic and chelating compounds. Take advantage of the benefits of high column efficiency and symmetrical peak shapes to reduce your analysis and method development time!
The ultra high purity Type B base silica contains negligible amounts of metal ion impurities. Combined with monomeric bonding chemistry, this silica makes the best general purpose Reversed Phase columns suitable for the most demanding separations in quality control as well as in research and development. |
Highlights
-
Ultra-pure silica cuts down on sample adsorption
-
High surface area (450m2/g) silica
-
Spherical 3 and 5µm particles with 100Å pores
-
Very high column efficiency
-
Moderate column back pressure
-
Two levels of hydrophobicity:
-
15% carbon (100V)
-
20% carbon (100Z)
-
Monomeric bonding chemistry
-
Low residual silanol content
|
TSKgel ODS-100V |
|
-
Lower than maximum C18 ligand density (15% C) improves wetting properties and prolongs retention of polar compounds
-
Can be used under 100% aqueous mobile phase conditions.
-
Best TSK-GEL column for challenging compounds, including acidic, basic, zwitterionic and chelating compounds.
|
- Monomeric bonding reaction followed by exhaustive endcapping results in:
- High C18 ligand density (20% C)
- Minimal silanol interaction
- Excellent lot-to-lot reproducibility
- Excellent general purpose TSK-GEL column for high throughput applications.
|
|
TSKgel ODS-100V
TSKgel ODS-100V provides longer retention for polar compounds than the higher coverage TSKgel ODS-100Z column. Proprietary monomeric bonded phase chemistry provides complete wetting and retention stability in 100% aqueous mobile phases. Inert silica surface prevents secondary interaction with metal impurities for improved efficiency and peak shape of basic, acidic and chelating compounds.
|
Structure:

Product Attributes:
| Pore size (mean): |
100Å |
Molecular Weight
Limit (Da) |
10,000 |
| End-capped: |
Yes |
| Particle size: |
3μm and 5μm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
Octadecylmethylsilane |
| % carbon |
15 |
Surface area
(m2/g) |
450 |
|
Literature:
Application Note -- High Throughput Reversed Phase HPLC Analysis of Caffeine using TSK-GEL ODS-140HTP and ODS-100V Columns
Application Note -- Unique Surface Treatment of Novel TSK-GEL ODS Columns Provide Separation of Aqueous & Fat Soluble Vitamins
Application Note -- TSK-GEL ODS-100V and 100Z for the analysis of basic compounds at low and neutral pH values
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, RPC Columns
Operating Conditions and Specifications
Performance Data -- TSKgel ODS-100Z and TSKgel ODS-100V Column Series Provides a Universal Solution for the Analysis of Samples Containing Acidic, Basic, Polar & Non-polar Compounds
Performance Data -- Novel Bonding Chemistry Imparts Enhanced Polar Selectivity to TSK-GEL ODS-100V Reversed Phase Columns
Performance Data -- Three Micron TSK-GEL ODS-100V Columns for High Throughput LCMS
Performance Data -- Efficient Reversed Phase Columns for High Throughput Analyses
Separation Report -- TSK-GEL ODS-100V and ODS-100Z Reversed Phase HPLC Columns
Technical Presentation -- Characteristics of Novel Three Micron ODS Columns for Analysis of Small MW Compounds
Technical Presentation -- LC/MS applications of newly developed, high performance ODS columns in pharmaceutical analysis
|
Applications |
Organic Acids

Antioxidants

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
21838 |
TSKgel ODS-100V |
3µm |
Stainless Steel |
1 |
3.5 |
21839 |
TSKgel ODS-100V |
3µm |
Stainless Steel |
1 |
5 |
21813 |
TSKgel ODS-100V |
3µm |
Stainless Steel |
2 |
3.5 |
21812 |
TSKgel ODS-100V |
3µm |
Stainless Steel |
2 |
5 |
21811 |
TSKgel ODS-100V |
3µm |
Stainless Steel |
2 |
7.5 |
| 21938 |
TSKgel ODS-100V |
3µm |
Stainless Steel |
2 |
10 |
|
TSKgel ODS-100V |
|
Stainless Steel |
2 |
15 |
|
TSKgel ODS-100V |
3µm |
Stainless Steel |
4.6 |
5 |
|
TSKgel ODS-100V |
|
Stainless Steel |
4.6 |
7.5 |
21940 |
|
|
Stainless Steel |
4.6 |
10 |
21829 |
TSKgel ODS-100V |
|
|
|
|
21457 |
|
5µm |
|
2 |
5 |
21458 |
TSKgel ODS-100V |
5µm |
|
2 |
|
21455 |
TSKgel ODS-100V |
|
|
|
|
|
|
|
Stainless Steel |
|
|
|
TSKgel ODS-100V Guard Cartridges for 2mmID columns, 3µm, 3 pk
|
|
|
|
1 |
|
TSKgel ODS-100V Guard Cartridges for 2mmID columns, 5µm, 3 pk
|
|
Stainless Steel |
|
|
|
TSKgel Guard Cartridge Holder for P/Ns 21814, 21841
|
|
|
2 |
1 |
|
TSKgel ODS-100V Guard Cartridges for 4.6mmID columns, 3 pk
|
|
Stainless Steel |
3.2 |
1.5 |
|
TSKgel Guard Cartridge Holder for P/N 21453
|
|
Stainless Steel |
3.2 |
1.5 |
|
|
2μm Super Series RP Silica (110Å)
TSK-GEL Super-ODS, Super-Octyl and Super-Phenyl columns are prepared from spherical 2µm silica particles with 140Å pore diameter. The silica beads in the columns are extremely uniform in size which provides column efficiencies of more than 160,000 plates per meter, yet have a pressure drop comparable to columns packed with 3µm particles. The main advantages of the Super Series columns are savings in time and solvent usage, in addition to the improved quantitation resulting from reduced band broadening.
Caution: The silica particles in Super Series columns have a relatively small pore volume, which results in shorter retention times than obtained on most other reversed phase columns. For instance, to achieve similar retention times as obtained on TSKgel ODS-100V, the percentage organic solvent in the mobile phase has to be reduced by about 20-30% on TSKgel Super-ODS columns. |
Highlights
-
The silica particles used in Super Series columns are uniform spherical 2µm beads with 140Å pores.
-
Pressure drop is not excessive due to the monodisperse particle size distribution.
-
Polymeric bonded phase structure and exhaustive endcapping effectively shields the solutes from interacting with residual silanol groups.
-
TSK-GEL Super Series require approximately 20% less organic solvent than other popular TSK-GEL reversed phase columns.
-
2µm particles provide superior resolution and speed, as well as improved sensitivity.
|
TSKgel Super-ODS |
|
|
Bonded with C18 functional groups and exhaustively endcapped. |
Bonded with C8 functional groups and exhaustively endcapped. |
Bonded with Phenyl functional groups and exhaustively endcapped. |
|
TSKgel Super-ODS
TSKgel Super-ODS columns are packed with monodispersed 2µm* spherical silica particles covalently bonded with octadecyl groups. The small particle size makes the Super series the highest efficiency reversed phase columns in the TSK-GEL product line. The monodispersed packing generates operational back pressures more typical of larger particles allowing the use of higher flow rates than other 2 micron packings
TSK-GEL Super-ODS is an excellent choice for small peptides, amino acids, tryptic digests, nucleotides, pharmaceutical molecules and food/beverage samples.
* nominal particle size; mean particle size is 2.3µm |
Structure:

Product Attributes:
| Pore size (silica): |
140Å |
| Exclusion Limit: |
20,000 Da |
| End-capped: |
Yes |
| Particle size: |
2μm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C18 (polymeric bonding chemistry) |
| % carbon |
8% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
Product Overview -- TSK-GEL Super Series Reversed Phase Columns
Separation Report -- TSK-GEL Super-ODS Packed Columns for Ultra-Fast Reversed Phase Liquid Chromatography
Technical Presentation -- A Highly Consistent and Chemically Stable Silica-based Octadecylsilane Stationary Phase for High Performance Liquid Chromatography: TSKgel Super-ODS Column for LC/MS
Application Overview -- Purification of Nucleic Acids
|
Applications |
Comparison of TSKgel Super-ODS to 3µm columns

Chromatogram of trypsin digest of
α-chymotrypsinogen on Super-ODS

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
|
TSKgel Super-ODS |
|
Stainless Steel |
1 |
|
19541 |
TSKgel Super-ODS |
2µm |
Stainless Steel |
2 |
5 |
19542 |
TSKgel Super-ODS |
2µm |
Stainless Steel |
2 |
10 |
19672 |
Guard Cartridge for P/Ns 19541, 19542 |
2µm |
Stainless Steel |
2 |
1 |
19308 |
Guard Cartridge holder for P/N 19672 |
|
Stainless Steel |
2 |
1 |
18154 |
TSKgel Super-ODS |
2µm |
Stainless Steel |
4.6 |
5 |
18197 |
TSKgel Super-ODS |
2µm |
Stainless Steel |
4.6 |
10 |
18207 |
Guardfilter for P/Ns 18154, 18197 |
2µm |
Stainless Steel |
4 |
0.4 |
18206 |
Guardfilter holder for P/N 18207 |
|
Stainless Steel |
4 |
0.4 |
|
|
TSKgel Super-Octyl
TSKgel Super-Octyl columns are packed with monodispersed 2µm* spherical silica particles covalently bonded with octyl groups. The small particle size makes the Super series the highest efficiency reversed phase columns in the TSK-GEL product line. The monodispersed packing generates operational back pressures more typical of larger particles allowing the use of higher flow rates than other 2 micron packings and offers less hydrophobicity than TSKgel Super-ODS.
TSK-GEL Super-Octyl is an excellent choice for peptides, proteins, amino acids, tryptic digests, nucleotides, pharmaceutical molecules and food/beverage samples
* nominal particle size; mean particle size is 2.3µm. |
Structure:

Product Attributes:
| Pore size (silica): |
140Å |
| Exclusion Limit: |
20,000 Da |
| Endcapped: |
Yes |
| Particle size: |
2μm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C8 (polymeric bonding chemistry) |
| % carbon |
5% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
Product Overview -- TSK-GEL Super Series Reversed Phase Columns
|
Applications |
Rapid separation of protein mixture on TSKgel Super-Octyl

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
20013 |
TSKgel Super-Octyl |
|
Stainless Steel |
2 |
5 |
20014 |
TSKgel Super-Octyl |
|
Stainless Steel |
2 |
10 |
42176 |
Guard Cartridge for P/Ns 20013, 20014 |
|
Stainless Steel |
2 |
1 |
19308 |
Guard Cartridge holder for P/N 42176 |
|
Stainless Steel |
2 |
1 |
|
TSKgel Super-Octyl |
|
Stainless Steel |
4.6 |
5 |
18276 |
TSKgel Super-Octyl |
|
Stainless Steel |
4.6 |
10 |
18207 |
Guardfilter for P/Ns 18275,18276 |
|
Stainless Steel |
4 |
0.4 |
18206 |
Guardfilter holder for P/N 18207 |
|
Stainless Steel |
4 |
0.4 |
|
|
TSKgel Super-Phenyl
TSKgel Super-Phenyl columns are packed with monodispersed 2µm* spherical silica particles covalently bonded with phenyl groups. The small particle size makes the Super series the highest efficiency reversed phase columns in the TSK-GEL product line. The monodispersed packing generates operational back pressures more typical of larger particles allowing the use of higher flow rates than other 2 micron packings and offers less hydrophobicity than TSKgel Super-Octyl and TSKgel Super-ODS.
TSK-GEL Super-Phenyl is an excellent choice for peptides, proteins, amino acids, tryptic digests, nucleotides, pharmaceutical molecules and food/beverage samples.
* nominal particle size; mean particle size is 2.3µm.
|
Structure:

Product Attributes:
| Pore size (silica): |
140Å |
| Exclusion Limit: |
20,000 Da |
| Endcapped: |
Yes |
| Particle size: |
2µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
Phenyl (polymeric bonding chemistry) |
| % carbon |
3% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
Product Overview -- TSK-GEL Super Series Reversed Phase Columns
|
Applications |
Rapid separation of protein mixture on TSKgel Super-Phenyl

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
20017 |
TSKgel Super-Phenyl |
2μm |
Stainless Steel |
2 |
5 |
20018 |
TSKgel Super-Phenyl |
|
Stainless Steel |
2 |
10 |
42177 |
Guard Cartridge for P/Ns 20017, 20018 |
|
Stainless Steel |
2 |
1 |
19308 |
Guard Cartridge holder for P/N 42177 |
|
Stainless Steel |
2 |
1 |
18277 |
TSKgel Super-Phenyl |
|
Stainless Steel |
4.6 |
5 |
|
TSKgel Super-Phenyl |
|
Stainless Steel |
4.6 |
10 |
18207 |
Guardfilter for P/Ns 18277, 18278 |
|
Stainless Steel |
4 |
0.4 |
18206 |
Guardfilter holder for P/N 18207 |
|
Stainless Steel |
4 |
0.4 |
|
|
Specialty RP Columns
TSKgel ODS-120A
TSKgel ODS-120A columns use a 150Å pore size silica base support. The silica's exclusion limit of 10,000 Da makes them a good choice for the reversed phase chromatography of peptides, small proteins, and environmental samples such as poly-aromatic hydrocarbons.
The "A" signifies that the material is not endcapped. For charged samples, the endcapped TSKgel ODS-120T column is a more suitable alternative.
Bonded phase pore size is indicated by the number in the product description, in this case TSKgel ODS-120A has 120Å nominal pore size.
|
Structure:

Product Attributes:
| Pore size (silica): |
150Å |
| Exclusion Limit: |
10,000 Da |
| Endcapped: |
no |
| Particle size (mean): |
5µm and 10µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C18 (polymeric bonding chemistry) |
| % carbon |
20% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Reversed Phase Columns
Operating Conditions and Specifications
|
Applications |
Separation of 16 poly-aromatic hydrocarbons on
TSKgel ODS-120A

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
07636 |
TSKgel ODS-120A |
5μm |
Stainless Steel |
4.6 |
15 |
07124 |
TSKgel ODS-120A |
5μm |
Stainless Steel |
4.6 |
25 |
|
Guard Cartridge for 4.6mm ID columns, 3 pk, Replaces P/N 14125 |
5μm |
Stainless Steel |
3.2 |
1.5 |
19018 |
Guard Cartridge holder for P/N 19005, Replaces P/N 14100 |
|
Stainless Steel |
3.2 |
1.5 |
|
TSKgel ODS-120A |
10μm |
Stainless Steel |
7.8 |
30 |
|
TSKgel ODS-120A |
|
Stainless Steel |
21.5 |
30 |
|
|
TSKgel ODS-120T
TSKgel ODS-120T columns use a 150Å pore size silica base support. The silica's exclusion limit of 10,000 Da makes them a good choice for the reversed phase chromatography of peptides, small proteins, and small molecular weight compounds in organic and environmental samples.
The columns are endcapped with trimethyl silane groups to improve the peak shape of negatively charged analytes.
Bonded phase pore size is indicated by the number in the product description, in this case TSKgel ODS-120T has 120Å nominal pore size.
|
Structure:

Product Attributes:
| Pore size (silica): |
150Å |
| Exclusion Limit: |
10,000 Da |
| Endcapped: |
Yes |
| Particle size (mean): |
5µm and 10µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C18 (polymeric bonding chemistry) |
| % carbon |
22% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
Separation Report -- Application of TSK-GEL Semi-Micro Columns for High-Sensitivity Analyses
|
Applications |
Purification and rapid analysis of synthetic peptides

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
18152 |
TSKgel ODS-120T |
5μm |
Stainless Steel |
2 |
15 |
18153 |
TSKgel ODS-120T |
5μm |
Stainless Steel |
2 |
25 |
19325 |
Guard Cartridge for PN's 18152, 18153 |
|
Stainless Steel |
2 |
1 |
|
Guard Cartridge holder for PN 19325 |
|
Stainless Steel |
2 |
1 |
|
TSKgel ODS-120T |
|
Stainless Steel |
4.6 |
15 |
07125 |
TSKgel ODS-120T |
|
Stainless Steel |
4.6 |
25 |
19006 |
Guard Cartridges for 4.6mm ID columns,
3 pk, Replaces P/N 14125 |
|
Stainless Steel |
3.2 |
1.5 |
19018 |
Guard Cartridge holder for PN 19006, Replaces P/N 14100 |
|
Stainless Steel |
3.2 |
1.5 |
07130 |
TSKgel ODS-120T |
|
Stainless Steel |
7.8 |
30 |
|
TSKgel ODS-120T |
10μm |
Stainless Steel |
21.5 |
30 |
|
|
TSKgel OligoDNA RP
Specifically designed for purification of oligonucleotides, RNA and DNA fragments (up to 500mer), TSKgel OligoDNA RP can provide excellent separations of samples with very similar sequences. The 250Å pore size provides excellent kinetics for molecules with helix shape structures processing large radii of gyration. The 5 micron particle size provides a minumum of 7,000 plates per 15 centimeter column.
|
Structure:

Product Attributes:
| Pore size (mean): |
250Å |
| Exclusion Limit: |
500mer |
| Endcapped: |
No |
| Particle size (mean): |
5µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C18 (monomeric bonding chemistry) |
| % carbon |
10% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
|
Applications |
Separation of octamers of similar sequence with TSKgel OligoDNA RP

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
13352 |
TSKgel OligoDNA RP |
5μm |
Stainless Steel |
4.6 |
15 |
13353 |
TSKgel OligoDNA RP |
5μm |
Stainless Steel |
7.8 |
15 |
|
|
TSKgel TMS-250
Featuring trimethylsilane groups covalently attached to large 250Å pores, TSKgel TMS-250 is an excellent choice for analysis of larger proteins by reversed phase HPLC. Due to the low hydrophobicity of the ligand, excellent recoveries are common even when used with large proteins. Proteins such as adolase (158kDa) exhibit sharp peaks relative to wide pore C18 columns.
|
Structure:

Product Attributes:
| Pore size (mean): |
250Å |
| Exclusion Limit: |
200,000 Da |
| Endcapped: |
Yes |
| Particle size (mean): |
10µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C1 (monomeric bonding chemistry) |
| % carbon |
5% |
|
Literature:
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Traditional Reversed Phase Columns
Operating Conditions and Specifications
|
Applications |
High resolution protein separation on TSKgel TMS-250

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
|
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
07190 |
TSKgel TMS-250 |
10μm |
Stainless Steel |
4.6 |
7.5 |
|
High Throughput RP Silica
TSKgel ODS-140HTP
TSKgel ODS-140HTP
TSKgel ODS-140HTP columns provide high resolution and short analyses time at moderate pressures, enabling high throughput separations. The polylayer bonding chemistry of the 2.3µm particle size of these columns results in highly efficient and durable columns. The lower pressure drop reduces the burden on the hardware, allowing the TSK-GEL ODS-140HTP columns to be used with either UPLC® (up to 9000psi) or conventional HPLC systems.
For use in high throughput applications, including drug discovery, pharmacokinetics and peptide digest separations, TSK-GEL ODS-140HTP columns offer excellent peak shape for basic compounds.
|
Structure:

Product Attributes:
| Pore size (silica): |
140Å |
| Endcapped: |
yes |
| Particle size: |
2.3µm |
| pH stability: |
2.0 - 7.5 |
| Functional group: |
C18 (polymeric bonding chemistry) |
| % carbon |
8% |
|
Literature:
Application Note -- High Throughput Reversed Phase HPLC Analysis of Caffeine using TSK-GEL ODS-140HTP and ODS-100V Columns
Application Note -- TSK-GEL ODS-140HTP, 2.3µm: Ultra High Performance Reversed Phase Columns for High Throughput Analysis
Application Note -- TSK-GEL ODS-140HTP, 2.3μm Columns for the Fast and Reliable Separation of Drugs Used in Cold and Sinus OTC Medicines
Brochure -- Reversed Phase and HILIC TSK-GEL HPLC Columns
Catalog -- Chromatography Catalog, Reversed Phase Columns
Operating Conditions and Specifications
Product Overview -- TSK-GEL ODS-140HTP Columns
Technical Presentation -- The Separation of Popular Cold, Sinus, and Allergy Medications using TSK-GEL ODS-140HTP Columns
|
Performance Data |
Column stability:
TSK-GEL ODS-140HTP columns are stable at high flow rates under demanding step gradient conditions.
Figure A shows that consistent theoretical plate values were obtained on the TSKgel ODS-140HTP column during 1110 gradient cycles consisting of five minute step gradients from 10% to 50% and from 50% to 100% methanol at 0.6mL/min. During each cycle, pressure fluctuated between 30 and 60MPa.
Figure A:

Figure B shows injections of test solutes after the first step gradient cycle and after 1110 cycles. The results clearly demonstrate the durability of the TSK-GEL ODS-140HTP columns when operated at high flow rate and high pressure.
Figure B:

|
|
|
Ordering information:
To order or get a price, please contact Søren Jensen, sorenj@md-scientific.dk, Mobile 2421 2559.
P/N |
Description |
Particle
size |
Housing material |
ID
(mm) |
Length
(cm) |
21927 |
TSKgel ODS-140HTP |
2.3μm |
Stainless Steel |
2.1 |
5 |
21928 |
TSKgel ODS-140HTP |
2.3μm |
Stainless Steel |
2.1 |
10 |
|
|
Startside for Tosoh kolonner
For flere detaljer og pris, kontakt venligst MD Scientific via e-mail: info@md-scientific.dk eller telefon: 7027 8565.
Top
|