TSK-GEL GPC columns are available in conventional 7.8mmID x 30cm Hxl and Hhr columns and in high efficiency, high throughput 6mmID x 15cm SuperH and SuperHZ columns. How the product lines compare to one another is shown below.

Comparison of TSK-GEL H-type resins

Series Type

SuperHZ

Hxl

SuperH

Hhr

Application focus

High-throughput polymer analysis with ultra low polymer adsorption, limited solvent compatibility range.

Conventional polymer analysis with ultra low polymer adsorption, limited solvent compatibility range

High-throughput polymer analysis with expanded solvent compatibility range.

Conventional polymer analysis with expanded solvent compatibility range.

Particle size

3, 5, and 10 micron, depending on pore size

5 and 9 micron, depending on pore size

3 and 5 micron, depending on pore size

5 micron

Theoretical plates 1

16,000/15cm column

16,000/30cm column

16,000/15cm column

16,000/30cm column

Maximum temperature

G1000--G3000, 60°C
G4000--Mixed, 80°C

G1000--G3000, 60°C
G4000--Mixed, 80°C

140°C

140°C

Standard shipping solvent

THF

THF2

THF

THF2

THF can be switched to

see table 1 (below) and note #3 for dichloromethane and dichloroethane

see table 1 (below)

 

Other shipping solvents available?

yes4

no

Number of solvent substitutions

One time only

 

Several5

 

Solvent exchange instructions

Linear gradient with a 2%/min rate of change with a flow rate of <0.25mL/min.

Linear gradient with a 2%/min rate of change with a flow rate of <0.5mL/min.

Linear gradient with a 2%/min rate of change according to flow rates in table 2 (below).

1) Theoretical plates listed are based on smallest particle size listed.
2) High-temperature columns (HT) are shipped with ODCB (o-dichlorobenzene) as standard shipping solvent.
3) Dichloromethane and dichloroethane are not available for G1000 pore size columns.
4) See Table 1 (below) for available shipping solvents
5) After switching to a very polar solvent such as acetone, switching back to a nonpolar solvent is not recommended.


Table 1: Solvent compatibility for TSK-GEL H-type columns

The column shipping solvent limits the types of solvents that can be used with each column type.

Column type

Shipping solvent*

Can be replaced with

SuperHZ and Hxl1

 

 

 

 

Tetrahydrofuran3,4

benzene, chloroform, toluene, xylene, dichloromethane, dichloroethane

Acetone**

carbon tetrachloride5, o-dichlorobenzene, dimethylformamide, dodecane, dimethyl sulfoxide, dioxane, ethylacetate, FC-113, hexane, pyridine, hexafluoroisopropanol/chloroform, methyl ethyl ketone, quinoline, cyclohexane

Chloroform**

m-cresol in chloroform, up to 10% hexafluoroisopropanol/chloroform

Dimethylformamide

dimethyl sulfoxide, dioxane, tetrahydrofuran, toluene

o-Dichlorobenzene

1-chloronaphthalene, trichlorobenzene

SuperH and Hhr2

Tetrahydrofuran3

acetone, ethanol, quinoline, benzene, o-dichlorobenzene, ethyl acetate, dodecane, FC-113, carbon tetrachloride5, dichloromethane, dichloroethane, trichloroethane, n-hexane, cyclohexane, xylene, tetrahydrofuran, chloroform, 1,4-dioxane, hexafluoroisopropanol, toluene, 1-chloronaphthalene, dimethylaceto acetamide, methyl ethyl ketone, trichlorobenzene, m-cresol, dimethylformamide, methylpyrrolidone, o-chlorophenol/chloroform, dimethyl sulfoxide, pyridine

SuperMultiporeHZ

Tetrahydrofuran3

Cannot be replaced.  SuperMultiporeHZ columns can be used only in Tetrahydrofuran

Notes:

1) In case of SuperHZ and Hxl, keep flow rate below <0.5mL/min during solvent change. Solvent can be changed one way/one time only.
2) In case of SuperH and Hhr, see Table 2 below for appropriate flow rates for solvent exchange. After switching to a very polar solvent, switching to a nonpolar solvent is not recommended.
3) All TSK-GEL Hxl, Hhr, SuperHZ, SuperH, SuperMultipore, and GMH analytical columns are shipped containing tetrahydrofuran (THF), except GMH-HT columns, which contain o-dichlorobenzene (ODCB).
4) THF in G1000Hxl columns cannot be replaced with dichloromethane or dichloroethane.
5) Prolonged exposure to carbon tetrachloride can corrode the stainless steel parts of a column and an HPLC system.

*  100% methanol cannot be used with H-type columns; use this solvent with TSK-GEL SW-type or Alpha-type columns.

** TSK-GEL H columns may be specially ordered with this shipping solvent.


Table 2: Recommended flow rates (mL/min) for solvent exchange in TSK-GEL SuperH and Hhr columns

Solvent

SuperH (6.0mmIDx15cm)

Hhr (7.8mmIDx30cm)

n-Hexane

0.5

0.9

methyl ethyl ketone

0.4

0.7

dichloromethane, ethyl acetate

0.35

0.6

toluene, chloroform

0.3

0.5

dimethylformamide

0.2

0.4

carbon tetrachloride, pyridine

0.15

0.3

dimethyl sulfoxide, dioxane, ethanol,
N-methylpyrrolidone, o-dichlorobenzene

0.1

0.2

quinoline, hexafluoroisopropanol,
1-chloronaphthalene

0.05

0.1

 